Sign In | Join Free | My burrillandco.com
Home > Telecom Rectifier System >

DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier

Tianjin Estel Electronic Science and Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier from wholesalers
     
    Buy cheap DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier from wholesalers
    • Buy cheap DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier from wholesalers
    • Buy cheap DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier from wholesalers
    • Buy cheap DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier from wholesalers
    • Buy cheap DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier from wholesalers
    • Buy cheap DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier from wholesalers

    DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier

    Ask Lasest Price
    Brand Name : ESTEL
    Model Number : M45D65B
    Certification : ISO9001, CE, 3C, FCC, TLC
    Price : 715-4286 usd
    Payment Terms : L/C, D/A, D/P, MoneyGram, T/T
    Supply Ability : 3,000 sets per month
    Delivery Time : 15-20 working days
    • Product Details
    • Company Profile

    DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier


    DC48V Rack Mount Rectifier High-Capacity M45D65B 220VAC Single Phase


    1. Rack Mount Rectifier Overview


    M45D65B is a 19-inch sub-rack for hybrid power system , with 2U height compact design to meet critical application needs of fiber and microwave transmission, access device, switch.

    The system’s maximum power is 90A, with AC input/DC input/battery/load MCBs. The cables are front accessing with MCB and busbar. This power system supplies power to -48V communication

    Equipment.


    2. System Parameter


    CategoryM45D65B
    SystemDimension(mm)482.0(W)*350.0(D)*2U(H)
    Weight≤15kg(without rectifier module)
    Cooling modeNatural cooling
    Installation modeInstalled on 19-inch rack or inside the cabinet
    IP GradeIP20
    AC DistributionInput Voltage220VAC single phase
    Input capacity1×50A/2P;MCB:C63A/2P
    Input frequency45~66Hz, rated 50/60Hz
    AC SPD20kA/40kA, 8/20μs
    DC DistributionOutput voltage-42~-58VDC,rated value:-53.5VDC
    Maximum capacity4.2kW(3*3000W rectifier module)
    Battery connection2×85A/2P;MCB:C63A/1P*2
    Load breakers6×50A/2P
    DC SPD10kA/, 8/20μs
    Rectifier moduleEfficiency≥96%
    Rated power1740W(176~300VAC)
    Working temperature-40℃~+75℃(fully output below 50℃)
    Dimension105.5mm(W)×286mm(D)×41.5mm(1U/H)
    Cooling modeForced cooling with fan
    ControllerSignal input4 AI(3 Battery temp., 1 ambient temp) ,6 DI(SPD, 6 common DI)
    Alarm output4 dry contact
    Communication portLAN/RS232/RS485 interface,LAN-SNMP,TCP/IP
    Display modeLCD
    EnvironmentOperating temperature-40℃~+65℃
    Storage temperature-40℃~+70℃
    Operating humidity0%~95%(non-condensing)
    Altitude0~3000m(If the altitude is within the range of 2000m to 3000m, the maximum operating temperature decreases by 1℃ as the altitude increases by 200m.)

    3. Telecom Rectifier Quick Details

    • Standard 19-inch width for versatile usage
    • 2U height compact design, saving space and installation costs
    • Front operation and cable access for convenient maintenance
    • Advanced battery management for prolonged battery life
    • Various communication ports for flexible networking and remote monitoring
    • Hot pluggable rectifier and controller for easy online maintenance
    • Wide input voltage range (85-300Vac) for adaptability to power grids

    4. Working Principles


    (1) AC input: Startup rectifier module after AC powered-on, outputs -48Vdc, at the same time charge the battery and power the conversion module, conversion module outputs 220Vac.


    Under normal conditions, the parameters of rectifier module and distribution unit are all under controll of the monitoring module, operating according to the preset parameters or user’s commands. If AC mains fault,

    the battery will power to the system, and continue outputing - 48 VDC and 220 vac, with the discharge of the battery, the voltage of the battery starts to descend, when the voltage is under 43.2 V + / - 0.5 V,

    the monitoring module send battery under-voltage signal and close the load output directly, then the power system will stop working. When external AC mains recovers,

    the system will normally work again. (All above monitoring data are system default values and can be reset by user)


    (2) -48V input: No AC current or no AC be connected, access external power -48V to -48V load port, startup monitoring and conversion module, 220Vac output.


    Figure Conceptual diagram


    5. Rectifier module


    The module panel


    (1) Power indicator

    (2) Alarm indicator

    (3) Fault indicator

    (4) Locking latch

    (5) Handle

    There are three indicator on the panel,which are used to reflect the operation status of the rectifier,see Table below for details.

    Table Rectifier indicator description


    IndicatorColorStatusReasons for abnormal status
    Power indicatorGreenNormally onThe module has and power input
    OffMain supply fault(no power input or OVP,UVP of power input).non-output
    Alarm indicatorYellowNormally onTemperature alarm(OTP when the ambient temperature>65℃)
    The module is hibernating. (indicator lighting, no alarm)
    The module is current-limiting
    FlickeringCommunication failure

    Fault

    indicator

    RedNormally on

    Non-output caused by module inner reason such as OVP, fan

    fault, OTP

    Normally offThe module is running properly.

    6. Controller-MC2600


    The MC2600 front panel


    • LAN port
    • RS485 port
    • Run indicator
    • Minor alarm indicator
    • Major alarm indicator
    • Handle
    • Buttons

    Table for controller button description


    ButtonDescription
    ESC

    Returns to the previous menu without saving the

    settings.

    Press the ESC and ENT button at the

    same time within a short period of

    time can restart the controller.

    ENT.


    Ø Enters the main menu from the standby

    screen.

    Ø Enters a submenu from the main menu.

    Ø Saves the menu settings.

    UP

    Turns to the previous menu or sets parameter

    values.

    When setting parameter values, you can hold down

    this button to quickly adjust values.

    When the parameter value is set by

    multiple string types, press up or

    down button to change each value.

    After setting the value, press the

    confirm button to move the cursor

    back automatically.

    DN.

    Turns to the next menu or sets parameter values.

    When setting parameter values, you can hold down

    this button to quickly adjust values.


    Describes the indicator on the controller panel is shown in table below


    TypeColorStateInstructions
    Run indicatorGreenFlickeringController is running properly
    OffController is fault or has no DC input
    Minor AlarmYellowNormally onThe controller generates a minor alarm
    OffThe controller does not generate any minor alarms
    Major alarmRedNormally onThe controller generates a major alarm
    OffThe controller does not generate any major alarms

    The controller provides two communication ports,

    The definition of RS485 communication port is shown in below table


    Pin No.12345678
    Signal nameRS485+-RS485------

    The LAN Ethernet port interface definition is shown in Table


    Pin No.12345678
    Signal nameTX+TX-RX+--RX---

    7. DI/DO Interface


    The DI/DO interface board front panel


    Digital input is submenu of parameter setting menu, which is mainly used for the operator to configure the input normal state of 8 digital switches in the system.


    Table Relay input parameter setting


    Digital No.Digital nameDI NormalDescription
    DI1HEX AlarmNOIt is normal when opened; and the alarm occurs when closed.
    DI2PWC Door AlarmNCIt is normal when opened; and the alarm occurs when closed.
    DI3BT AlarmNOIt is normal when opened; and the alarm occurs when closed.
    DI4BC AlarmNOIt is normal when opened; and the alarm occurs when closed.
    DI5Digital5 AlarmNOIt is normal when opened; and the alarm occurs when closed.
    DI6Genset on AlarmNOIt is normal when opened; and the alarm occurs when closed.
    DI7DC SPD AlarmNCIt is normal when opened; and the alarm occurs when closed.

    Relay output is submenu of parameter setting menu, which is mainly used for the operator to configure the output normal state of 8 relays in the system.


    Table Relay output parameter setting


    Digital No.Digital NameAlarm codeDescription
    DO1Relay output 1NCClosed when normal,opened when associated alarm occurs.
    DO2Relay output 2NCClosed when normal,opened when associated alarm occurs.
    DO3Relay output 3NCClosed when normal,opened when associated alarm occurs.
    DO4Relay output 4NCClosed when normal,opened when associated alarm occurs.
    DO5Relay output 5NCClosed when normal,opened when associated alarm occurs.
    DO6Relay output 6NCClosed when normal,opened when associated alarm occurs.
    DO7Relay output 7NCClosed when normal,opened when associated alarm occurs.

    In addition, the product provides 6 other ports.


    Table Other intput parameter setting


    Parameter nameSetting description
    BTEMP 1Battery sensor1 port
    BTEMP 2Battery sensor2 port
    ENV_TEMPEnveropment sensor port
    12V +/-12V power supply is provided
    RS485RS485 port, reserved interface, no protocol definition
    OIL+/-Connect the oil level sensor

    Wiring methods:

    Ø Remove the cable insulation with wire stripping pliers. The exposed length of the cable core shall not be less than 10 mm.

    Ø Press the button above the terminal with the screwdriver, insert the cable, release the screwdriver and complete the cable connection.

    Ø With handle gently pull cables, to ensure that the cable does not fall off.


    8. Installing Subrack


    Install the subrack to the 19-inch rack, as shown in Figure below.

    Ø Step 1,Remove the plug from the package.

    Ø Step 2,Push the plug into the 19-inch rack

    Ø Step 3,Install the fixed screw (if the mounting hole of the plug frame ear does not correspond to the position of the floating nut of the frame, it needs to be adjusted according to the actual installation).


    Install Rectifier module


    Ø Step 1,Take out the module from the package.

    Ø Step 2,Hold the module handle on the front panel and put the module onto the slot.

    Ø Step 3,Push the module module slowly to the front panel of the module and flush with the power

    distribution panel.

    Ø Step 4,Tighten the fixing screw on the module panel so that the module does not come off.



    9. Packing and Shipping

    Package use free fumigation woodcase which is suitable for export. This package is anti moisture, anti impact and srong to ensure safe transportation.


    Quality DC48V Rack Mount Rectifier High Capacity M45D65B 220VAC Telecom Single Phase Rectifier for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)