Sign In | Join Free | My burrillandco.com
Home > Telecom Power System >

Telecom Rack Mount Rectifier System For Satellite Communication Ground Station

Tianjin Estel Electronic Science and Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Telecom Rack Mount Rectifier System For Satellite Communication Ground Station from wholesalers
     
    Buy cheap Telecom Rack Mount Rectifier System For Satellite Communication Ground Station from wholesalers
    • Buy cheap Telecom Rack Mount Rectifier System For Satellite Communication Ground Station from wholesalers
    • Buy cheap Telecom Rack Mount Rectifier System For Satellite Communication Ground Station from wholesalers

    Telecom Rack Mount Rectifier System For Satellite Communication Ground Station

    Ask Lasest Price
    Brand Name : ESTEL
    Model Number : GPE48350G
    Certification : ISO9001, CE, 3C, FCC, TLC
    Price : 715-4286 usd
    Payment Terms : L/C, D/A, D/P, , T/T, Western Union
    Supply Ability : 20,000 sets per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Telecom Rack Mount Rectifier System For Satellite Communication Ground Station


    Telecom Rack Mount Rectifier System For Satellite Communication Ground Station


    Quick Details:


    Place of Origin: Shenzhen, China (Mainland)Input Voltage: AC220V
    Brand Name: ESTELOutput Voltage: DC48V
    Model Number: GPE48350GOutput Power: 18725W
    Product Name: Telecom Rectifier SystemInput Frequency 45~65Hz
    Certification: ISO9001, CE, 3C, FCC, TLCMax. Input Current: 40A
    Installation Mode: embeddedPower Factor: 0.98
    Application: outdoor telecom cabinet

    Components:

    7×50A rectifier module,

    1×monitoring module,

    power distribution


    Payment & Shipping Terms:


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:L/C, D/A, D/P, T/T, Western Union
    Supply Ability:20,000 sets per month
    Delivery Time:7-10 working days
    Packaging Details:carton/wooden case

    1. System Configuration


    The system consists of power distribution unit, rectifier module (from 1 set, up to 7 sets) and 1 monitoring module. The configuration is optional, as following table:


    ConfigurationRectifier ModuleMonitoring ModulePower Distribution
    StandardGPR4850DGPM48P (With Ethernet Port)

    AC power distribution: single phase input, AC breaker @ general line (100A/2P);

    DC power distribution: battery 100A*4(fuse);

    LVLD: 63A×3 32A×5 16A×4 (MCB capacity optional)

    LVBD: 32A×3 16A×4(MCB capacity optional)

    2. Operating Principle


    AC power is first input AC-INPUT MCB and then feed into the rectifier module after lightning proof and filtering. AC-INPUT acts as protection to over load and short circuit to AC power. The user’s battery is connected to the DC output side through MCB BAT and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.

    Under normal conditions, every parameter of rectifier modules and power distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains faults, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When battery voltage is under -47V±0.5V, the monitoring module sends DC under voltage alarm signal and when battery voltage is under -46.0V±0.5V (adjustable), the KM1cuts off non-priority loads and retaining power to priority loads. If battery voltage drops to -43.0V±0.5V (adjustable), the KM2 will cut off output of priority loads and then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).
    Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding.

    3. System Properties


    Environment
    ItemMin.TypicalMax.UnitRemark
    Operating temperature-2555°CWhen ≥55°C, decreased power output
    Storage temperature-4080°C
    Humidity1090%Relative humidity without condensing
    Atmospheric pressure70106KPa
    Altitude03000m
    CoolingForced cooling with fan

    Input
    ItemMin.TypicalMax.UnitRemark
    Input voltage range90220290Vac
    Input frequency455065Hz
    Max. Input current40A
    Power factor0.98Rated load
    Input over voltage protection point300VacAutomatically recoverable
    Input over voltage recovery point290VacReturn difference ≥5V
    Input under voltage protection point85VacAutomatically recoverable
    Input under voltage recovery point90VacReturn difference ≥5V
    Input over current protectionMCB in AC Input supply protection

    Output (Table 1)
    ItemMin.TypicalMax.UnitRemark
    Output voltage4253.558VdcAdjustable by monitor, tested in no load
    Output power18725W18725W output when input voltage is 176~290VAC (rated power includes battery charging power plus load power)
    9350W90~175VAC input
    Output over voltage protection point58.560.5VdcLock up
    Output current limiting protection pointOutput current limiting protection
    Output short circuit protectionLong-term short circuit protection, automatically recoverable
    Over temperature protectionAutomatically recoverable in ambient temperature lower than 65°C
    Battery power-down protectionBattery power-down protection
    Battery polarities reversal connection protectionNo damage on battery and power system
    Voltage regulation accuracy±1%

    Output (Table 2)
    ItemMin.TypicalMax.UnitRemark
    Temperature coefficient±0.2‰/℃
    Current sharing unbalance±5%Within 50~100% load range
    Start-up/shut-down overshoot range±5%Any module is removed when operating, (the load current should be less than total output current of working rectifier modules), the system output voltage fluctuates
    Dynamic response recovery time200uS

    25%~50%~25% load variation

    50%~75%~50% load variation

    Dynamic response overshoot±5%Rated output voltage, rated load current
    Efficiency9192%220Vac input, rated output voltage, rated load current
    83%110Vac input, rated output voltage, rated load current
    Start-up time38Spre-current limiting is fitted with start-up output between rated start up input voltage and rated output voltage established period
    Pressure drop500mV
    Peak-peak noise voltage200mV
    Psophometrically weighted noise voltage2mV

    Other Parameters
    ItemRequirement
    Acoustic noise≤55dB(A)
    Smellingany abnormal and poisonous smelling is not allowed
    Componentsrated temperature of the electrolytic capacitor ≥105℃
    Hot swappablethe rectifier module meets the hot-swappable requirement
    Mixed insertionrectifier modules can be mixed insertion
    Ineffective separationrectifier module can separate with system when it is ineffective
    Coolingforced cooling by fan mounted on rectifier, face in, back out. The fan is mounted on rectifier front panel; can be disassembled. Fans include temperature control speed adjusting function.

    Insulation Rating
    ParametersMin.TypicalMax.UnitRemark
    Input-chassis3535Vdc
    Input-output3535Vdc
    Output-chassis1414Vdc
    Insulating ResistanceIn normal atmospheric pressure, when relative humidity is 90%, testing voltage is 500VDC, the insulating resistance of input-output, input-grounding, output-grounding are all ≥10MΩ

    4. Mechanical Properties


    Mechanical specifications
    Dimensions (Overall)as the following diagram
    Weight(kg)(Overall)

    ≤43.5kg (Inclusive of module)

    ≤25kg (Frame + Distribution, exclusive of module)


    5. Electrical Connection

    Chassis connects with external electric through system interface board. As shown in figure below:



    MCB descriptions:


    1. Single-phase AC input MCB and rail type connector;

    2. AC SPD;

    3. LOAD (-): system load- (7 MCBs,LVBD);

    4. LOAD (+): system load+ and BAT (+): battery+ (copper bar at front of system)

    5. LOAD (-): system load- (12 MCBs,LVLD);

    6. BAT (-): battery- (fuse)


    6. Application


    (1) Small scale program controlled exchangers

    (2) Access network

    (3) Transmission equipment

    (4) Mobile communication

    (5) Satellite communication ground station

    (6) Microwave communication


    7. Feature


    (1) Adoption of active power factor compensation technology with factor >0.98

    (2) Wide operating range of AC input voltage: 90~290Vac

    (3) Operating temperature range: -25°C~+55°C

    (4) Zero current/voltage switching tech with high efficiency ≥91%

    (5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.

    (6) Hot-swappable

    (7) Input over/under voltage protection

    (8) Output over voltage protection

    (9) Output over current protection

    (10) Output short circuit protection

    (11) Auto current sharing, parallel output

    (12) Embedded mounting


    8. Packing and Shipping



    Our Delivery Agent


    The goods can be shipped by sea, by air, by courier, by land, by train, etc.

    Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


    9. Our Contact Information


    Mobile Phone: 0086-13752765943

    Telephone: 0086-0755 66600941

    Email: info@estel.com.cn

    lxf.estel@hotmail.com
    Skype: fiona.liang10

    Quality Telecom Rack Mount Rectifier System For Satellite Communication Ground Station for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)