Sign In | Join Free | My burrillandco.com
Home > Telecom Power System >

Professional Telecom Rectifier Module System DC48V Remote Monitoring

Tianjin Estel Electronic Science and Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Professional Telecom Rectifier Module System DC48V Remote Monitoring from wholesalers
     
    Buy cheap Professional Telecom Rectifier Module System DC48V Remote Monitoring from wholesalers
    • Buy cheap Professional Telecom Rectifier Module System DC48V Remote Monitoring from wholesalers
    • Buy cheap Professional Telecom Rectifier Module System DC48V Remote Monitoring from wholesalers

    Professional Telecom Rectifier Module System DC48V Remote Monitoring

    Ask Lasest Price
    Brand Name : ESTEL
    Model Number : GPE48150A
    Certification : ISO9001, CE, 3C, FCC, TLC
    Price : 715-4286 usd
    Payment Terms : L/C, D/A, D/P, T/T, Western Union
    Supply Ability : 20,000 sets per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Professional Telecom Rectifier Module System DC48V Remote Monitoring


    Professional Telecom Rectifier Module System DC48V Remote Monitoring


    Quick Details:


    Place of Origin: Shenzhen, China (Mainland)Input Voltage: AC220V
    Brand Name: ESTELOutput Voltage: DC48V
    Model Number: GPE48150AOutput efficiency:92%
    Product Name: Telecom Rectifier SystemInput Frequency 45~65Hz
    Certification: ISO9001, CE, 3C, FCC, TLCMax. Input Current: 50A
    Installation Mode: 19”cabinet installedPower Factor: 0.98
    Application: outdoor telecom cabinet

    Components:

    5×30A rectifier module,

    1×monitoring module

    power distribution


    Payment & Shipping Terms:


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:L/C, D/A, D/P, T/T, Western Union
    Supply Ability:20,000 sets per month
    Delivery Time:7-10 working days
    Packaging Details:carton/wooden case

    1. Application


    (1) Small scale program controlled exchangers

    (2) Access network

    (3) Transmission equipment

    (4) Mobile communication

    (5) Satellite communication ground station

    (6) Microwave communication


    2. Features


    (1) Adoption of active power factor compensation technology with factor >0.98

    (2) Wide operating range of AC input voltage: 90~290Vac

    (3) Operating temperature range: -25°C~+55°C

    (4) Zero current/voltage switching tech with high efficiency ≥91%

    (5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.

    (6) Hot-swappable

    (7) Input over/under voltage protection

    (8) Output over voltage protection

    (9) Output over current protection

    (10) Output short circuit protection

    (11) Auto current sharing, parallel output

    (12) Embedded mounting


    3. Description


    The GPE48150A embedded power system consists of the power distribution frame, monitoring module and rectifier module. The whole system is of high reliability and performance, and can be operated through PC software.

    4. GPE48150A System Configuration


    GPE48150A consists of power distribution unit, rectifier module (from 1 set, up to 3 sets) and 1 monitoring module. The configuration is optional, as following table:


    ConfigurationRectifier ModuleMonitoring ModulePower DistributionRemark
    StandardGPR4830AGPM48DI (With Ethernet Port)

    AC power distribution: single phase 3 wire input, main power 2 phase AC MCB (50A);

    DC power distribution: battery fuse 80A×1;

    LVLD: 40A×3

    LVBD: 10A×1

    For details, please refer to the specifications of modules.
    Optional 1GPR4810AGPM48D (Without Ethernet Port)
    Optional 2GPR4815A
    Optional 3GPR4820A

    5. GPE48150A Operating Principle


    AC power is first input AC-INPUT MCB and then feed into the rectifier module after lightning proof and filtering. AC-INPUT acts as protection to over load and short circuit to AC power. LOAD1-, LOAD2-, LOAD3-, LOAD4- are connected with two load down contactor KM1, KM2. The user’s battery is connected to the DC output side through MCB BAT and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.


    Under normal conditions, every parameter of rectifier modules and power distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains faults, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When battery voltage is under -47V±0.5V, the monitoring module sends DC under voltage alarm signal and when battery voltage is under -46.0V±0.5V (adjustable), the monitoring module will control the contactor KM1 to cut off LOAD3 and LOAD4 and retains power to LOAD1 and LOAD2 . If battery voltage drops to -43.0V±0.5V (adjustable), the monitoring module will control the contactor KM2 to cut off output of LOAD1 and LOAD2, then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).


    Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding.


    6. GPE48150A Properties


    Input
    ParameterMin.TypicalMax.UnitRemark
    Input voltage range90220285Vac
    Input frequency455065Hz
    Input current50A
    Power factor0.98

    Output
    ParameterMin.TypicalMax.UnitRemark
    Output voltage range4253.558Vdc
    Output current range0150A176~285VAC
    075A90~175VAC
    Ripple (Vp-p)200mvAt rated input/output, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz.
    Output efficiency9092%220Vac input
    8385%110Vac input
    Regulation±1%
    Load regulation±1%
    Line regulation±1%

    Insulation rating
    ParameterMin.TypicalMax.UnitRemark
    Input-chassis2121Vdc
    Input - output2121Vdc
    Output - chassis750Vdc
    Insulation resistanceAt normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ

    Ambient requirements
    ParametersMin.TypicalMax.UnitRemark
    Operating temp-2555°CWhen ≥55°C, derating output
    Storage tempStorage temperature-4080°C
    Relative humidity1090%no condensing
    Atmospheric pressure70106KPa
    Altitude03000m
    Cooling methodForced cooling with fan

    Mechanical specifications
    Dimensions (mm)482.6mm×255mm×130.5mm
    Weight (kg)

    ≤11kg (Inclusive of module)

    ≤5.175kg (Frame + Distribution, exclusive of module)


    7. Electrical Connection Instruction


    Chassis connects with external electric through system interface board. As shown in figure below:



    Wiring Terminal Instruction:

    • LOAD(+): system load anode; LOAD(-): system load cathode;
    • BATT(+) and BATT(-) are battery interface

    8. Packing and Shipping




    Our Delivery Agent

    The goods can be shipped by sea, by air, by courier, by land, by train, etc.
    Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

    9. Our Contact Information

    Mobile Phone: 0086-13752765943
    Telephone: 0086-0755 66600941

    Email: info@estel.com.cn

    lxf.estel@hotmail.com
    Skype: fiona.liang10

    Quality Professional Telecom Rectifier Module System DC48V Remote Monitoring for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)