Sign In | Join Free | My burrillandco.com
Home > Telecom Rectifier System >

90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection

Tianjin Estel Electronic Science and Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection from wholesalers
     
    Buy cheap 90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection from wholesalers
    • Buy cheap 90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection from wholesalers
    • Buy cheap 90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection from wholesalers
    • Buy cheap 90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection from wholesalers
    • Buy cheap 90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection from wholesalers
    • Buy cheap 90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection from wholesalers
    • Buy cheap 90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection from wholesalers

    90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection

    Ask Lasest Price
    Brand Name : ESTEL
    Model Number : GPE4890J
    Certification : ISO9001, CE, 3C, FCC, TLC
    Price : 715-4286 usd
    Payment Terms : L/C, D/A, D/P, , T/T, Western Union
    Supply Ability : 20,000 sets per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection


    90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection​


    Quick Details:


    Place of Origin: Shenzhen, China (Mainland)Input Voltage: AC220V
    Brand Name: ESTELOutput Voltage: DC48V
    Model Number: GPE4890JOutput Power: 4800W
    Product Name: Telecom Rectifier SystemInput Frequency: 45~65Hz
    Certification: ISO9001, CE, 3C, FCC, TLCInput Current: 42A
    Installation Mode: 19”Power Factor: 0.99
    Application: outdoor telecom cabinet

    Components:

    3×30A rectifier module,

    1×monitoring module,

    power distribution


    Payment & Shipping Terms:


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:L/C, D/A, D/P, , T/T, Western Union
    Supply Ability:20,000 sets per month
    Delivery Time:7-10 working days
    Packaging Details:carton/wooden case

    1. GPE4890J System Configuration


    GPE4890J consists of distribution unit, rectifier module (up to 3 sets) and 1 monitoring module. The configuration is optional, as following table:


    ConfigurationRectifier ModuleMonitoring ModulePower DistributionRemark
    StandardGPR4830GPM48VI (With Ethernet Port)

    4P output terminal (1×anode, 1×LVLD cathode, 1×LVBD cathode, 1×battery cathode ).


    For details, please refer to the specifications of modules.
    Optional 1GPR4830
    Optional 2GPR4815
    Optional 3GPR4820

    2. GPE4890J Working Principle


    After AC power is controlled by the AC hydraulic switch and then through the EMI board lightning protection and filtering processing, into the rectifier module, AC hydraulic switch has the function of overload and short circuit protection to AC power.


    Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under -46.2V±0.5V, the monitoring module reports battery under voltage alarm signal; When the battery voltage is under -45.6V±0.5V, close LVLD load output; When the battery voltage is under -43.2V±0.5V, close LVBD load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).


    3. GPE4890J System Properties


    Input
    ParameterMin.TypicalMax.UnitRemark
    Input voltage range90220280VacNominal operating voltage range 100V-240V
    128280396VdcSupport DC input
    Input frequency455065HzAC input
    Start inrush current42AWhen 25°C Cold start, 280Vac input, full load test
    Power factor0.99

    Output
    ParameterMin.TypicalMax.UnitRemark
    Output voltage setting-53.5Vdc
    Output voltage range-43.2-53.5-57.6Vdc
    Output current range090A176~280VAC/176-396Vdc input
    045A90-<176Vac/128~<176Vdc input
    Ripple (Vp-p)200mvAt low temperature operating for 1 hour, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, 20MHz frequency band 20cm twisted pair.
    Output efficiency91%220Vac/280Vdc input,rated output
    85%110Vac/200Vdc input, 33A output
    Regulation±2%
    Load regulation±2%
    Voltage regulation±1%
    Output power4800W176-285Vac/176-396Vdc input
    2400W90-<176Vac/128~<176Vdc input (configure GPR4830A1)

    Insulation rating
    ParameterMinRemark
    Input - output3535Vdc/10mA//1minNo fly arc, no breakdown. Before the test, all the lightning protection and surge protection devices shall be cut off from the test points, and any rectifier module and monitoring unit should not be installed.
    Input-chassis3535Vdc/10mA//1min
    Output - chassis1414Vdc/10mA//1min
    Insulation resistanceAt normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ

    Ambient requirements
    ParametersMin.TypicalMax.UnitRemark
    Operating temp-2055°C≥ 55°C, output with derating power
    Storage tempStorage temperature-4080°C
    Humidity1090%Relative humidity, no condensing
    Atmospheric pressure70106KPa
    Altitude03000m
    Cooling methodForced cooling with fan
    Ingress protectionThe unit can operate when the diameter of dust particle is more than 5µm, with density ≤3*104 /m3. The dust shall not be conducting, electromagnetic or corrosive. The product don’t have waterproof function.

    Mechanical specifications
    Dimensions (Overall)482.6mm×265mm×88.1mm
    Weight(kg) (Overall)

    ≤11kg (Inclusive of module)

    ≤5.175kg (Frame + Distribution, exclusive of module)



    4. Application


    (1) Small scale program controlled exchanger

    (2) Access network

    (3) Transmission equipment

    (4) Mobile communication

    (5) Satellite communication ground station

    (6) Microwave communication

    5. Features


    (1) Adoption of active power factor compensation technology with factor >0.99

    (2) Wide operating range of AC input voltage: 90~280Vac

    (3) Operating temperature range: -25°C~+55°C

    (4) Zero current/voltage switching tech with high efficiency ≥91%

    (5) Perfect battery management, charge & discharge management, battery temperature compensation, low voltage protection, extend battery lifetime

    (6) Hot-swappable

    (7) The monitor has sleeping function, saving energy.

    (8) Input over/under voltage protection

    (9) Output over voltage protection

    (10) Output over current protection

    (11) Output short circuit protection

    (12) Embedded mounted

    6. Electric Connection


    Chassis connects with external electric through system interface board. As shown in figure below:



    Wiring terminal Connection Instruction:

    SPD: lightning arrester; L: live line; N: neutral line; transfer switch: lithium battery and lead acid battery transfer switch,switch to I - lithium battery; O - lead acid battery;


    Signal input output terminal definition as the right:


    FU1: battery fuse; LOADF: load fuse; 12V-12V power supply; SPD: lightning arrester signal;1-4: dry contact output.


    Output terminal definition as the right:


    BAT-: battery cathode; LOAD2-: LVBD cathode; LOAD1-: LVLD cathode; +: Load and battery cathode


    7. Packing and Shipping



    Our Delivery Agent

    The goods can be shipped by sea, by air, by courier, by land, by train, etc.
    Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

    8. Our Contact Information

    Mobile Phone: 0086-13752765943
    Telephone: 0086-0755 66600941

    Email: info@estel.com.cn

    lxf.estel@hotmail.com
    Skype: fiona.liang10

    Quality 90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)