Sign In | Join Free | My burrillandco.com
Home > Telecom Rectifier System >

Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification

Tianjin Estel Electronic Science and Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification from wholesalers
     
    Buy cheap Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification from wholesalers
    • Buy cheap Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification from wholesalers
    • Buy cheap Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification from wholesalers

    Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification

    Ask Lasest Price
    Brand Name : ESTEL
    Model Number : GPE48150G
    Certification : ISO9001, CE, 3C, FCC, TLC
    Price : 715-4286 usd
    Payment Terms : L/C, D/A, D/P, , T/T, Western Union
    Supply Ability : 20,000 sets per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification


    Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification


    Quick Details:


    Place of Origin: Shenzhen, China (Mainland)Input Voltage: AC220V
    Brand Name: ESTELOutput Voltage: DC48V
    Model Number: GPE48150GOutput current:150A
    Product Name: Telecom Rectifier SystemInput Frequency 45~65Hz
    Certification: ISO9001, CE, 3C, FCC, TLCMax. Input Current: 50A
    Installation Mode: embeddedPower Factor: 0.98
    Application: outdoor power cabinet

    Components:

    5×30A rectifier module,

    1×monitoring module,

    power distribution


    Payment & Shipping Terms:


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:L/C, D/A, D/P, T/T, Western Union
    Supply Ability:20,000 sets per month
    Delivery Time:7-10 working days
    Packaging Details:carton/wooden case

    1. GPE48150G System Configuration


    The system consists of distribution unit, rectifier module (1 min.,5 set max.) and monitoring module. The configuration is optional, as following table:


    ConfigurationRectifier ModuleMonitoring ModuleDistributionRemark
    StandardGPR4830A1 / GPR4830AGPM48D-232(With RS232 Port)

    AC distribution: 1-phase, 3-wire input, 1-pole

    AC MCB(63A);

    DC distribution: Battery fuse 100A×1;

    LVLD: 63A×3

    LVBD: 10A×2

    For details, please refer to the specifications of modules.
    Optional 1GPR4810A1GPM48D(without Ethernet port)
    Optional 2GPR4815A
    Optional 3GPR4820A

    2. Operating Principle


    AC mains is first input AC-INPUT MCB and then fed into the rectifier module after the SPD and EMI filtering. AC-INPUT acts as protection to over load and short circuit to AC power. The LOAD1-,LOAD2-,LOAD3-,LOAD4-,LOAD5- link in series to 2 power-off contactors KM1,KM2.The user’s battery is connected to the DC output side through MCB BAT and KM2, and the MCB provides disconnection control, over-load and short-circuit protection to the battery.

    Under normal conditions, every parameter of rectifier modules and distribution unit are controlled by the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When the voltage is under -47V±0.5V, the monitor reports DC under voltage alarm signal and when the voltage is under -46.0V±0.5V (adjustable), the KM1cuts off LOAD3-,LOAD4-,LOAD5- and retaining power to LOAD1-,LOAD2-. If the voltage drops to -43.0V±0.5V (adjustable), the KM2 will cut off output of LOAD1-,LOAD2- and then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).
    Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default setting, users can send command to activate or inactivate according to the demanding. To avoid the thunder and thunder surge pulse current break the power system, and match to the thunder protection module ideally, we must load decoupler on output port independently or keep some length cable.

    3. GPE48150G Properties

    Input
    ParameterMin.TypicalMax.UnitRemark
    Input voltage range90220280Vac
    Input frequency455065Hz
    Input current50A
    Power factor0.98

    Output
    ParameterMin.TypicalMax.UnitRemark
    Output voltage range-42-53.5-58Vdc
    Output current range0150A176~280VAC
    075A90~<176VAC
    Ripple (Vp-p)200mVRated input/output, apply 0.1uF film capacitor and 10uF high frequency electrolyte capacitor, oscilloscope band width of 20MHz.
    Output efficiency9092%220Vac input
    8385%110Vac input
    Regulation±1%
    Load regulation±1%
    Line regulation±1%

    Insulation rating
    ParameterRequirementRemark
    Input - output2121 Vdc
    Input-chassis2121 Vdc
    Output - chassis750 Vdc
    Insulation resistance@ normal atmospheric pressure, relative humidity: 90% Testing voltage: 500v dc insulation of input-output, input-ground, output-ground shall not be less than 10MΩ

    Environment
    ParametersMinTyp.MaxUnitRemark
    Operating temp-2555°CFor temperature≥55°C, output with power derating
    Storage tempStorage temperature-4080°C
    Humidity1090%Relative humidity, no condensing
    Atmospheric pressure70106KPa
    Altitude03000m
    Cooling methodCooled by fan
    Waterproof and dustproofIn the following condition, the equipment can work normally:5um diameter greater than the dust concentration is less than or equal to 3 × 104 /m3,The dust particles are not conductive, magnetic and corrosion;Not waterproof.

    Notes:

    (1) when the system working temperature at 55℃~65℃,the rectifier power automatic derating; when 65℃, 176~280 Vac range capable of long-term regulated output at least 80% rated power;

    (2) when 55 ℃ ,the rectifiers can be output maximum power and normal operation, not over temperature protection and parts stress meet the requirements.;

    (3) Because of the characteristics of liquid crystal, liquid crystal work beyond the temperature range, the screen may appear bright or dark no display case;

    (4) A large number of dust entering the rectifiers, may cause internal short circuit and over temperature protection. Therefore, in the dust more places, please note that dust control measures, and regular cleaning dust-proof net and the rectifiers internal dust..


    Mechanical specifications
    Dimensions (Overall)482.6mm×253.0mm×130.5mm
    Weight(kg)(Overall)

    ≤18.5kg(Inclusive of module)

    ≤8.5kg( Frame + Distribution, exclusive of module)




    4. Electric Connection


    Chassis connects with external electric through system interface board. As shown in figure below:



    Cable connetors descriptions:

    (1) N is the natural wire, L is the live wire,PE is the ground wire

    (2) B1- and B2- is the BATT (-),B1+ and B2+ is the BATT (+)

    (3) 1-,2-,3-,4-,5- are LODA1, LODA2…LODA5 load (-)

    (4) 1+,2+,3+,4+,5+ are LOAD1, LOAD2…LOAD5 load (+)


    5. Application


    (1) Small scale program controlled exchanges

    (2) Access network

    (3) Transmission equipment

    (4) Mobile communication

    (5) Satellite communication ground station

    (6) Microwave communication


    6. Features


    (1) Adoption of active power factor compensation technology with factor >0.98

    (2) Wide operating range of AC input voltage: 90~280Va

    (3) Operating temperature range: -25°C~+55°C

    (4) Zero current/voltage switching tech with high efficiency ≥92%

    (5) Perfect battery management prolongs battery lifetime: charge/discharge management, battery temperature compensation, battery capacity test, low-voltage protection

    (6) Hot-swappable

    (7) Input under/over voltage protection

    (8) Output over voltage protection

    (9) Output over current protection

    (10) Output short circuit protection

    (11) Auto current sharing, parallel operation

    (12) Embedded mounted

    (13) Perfect surge protection function 20KA (8/20 US)


    7. Packing and Shipping




    Our Delivery Agent

    The goods can be shipped by sea, by air, by courier, by land, by train, etc.
    Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

    8. Our Contact Information

    Mobile Phone: 0086-13752765943
    Telephone: 0086-0755 66600941

    Email: info@estel.com.cn

    lxf.estel@hotmail.com
    Skype: fiona.liang10

    Quality Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)