Sign In | Join Free | My burrillandco.com
Home > Outdoor Telecom Cabinet >

Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving

Tianjin Estel Electronic Science and Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving from wholesalers
     
    Buy cheap Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving from wholesalers
    • Buy cheap Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving from wholesalers
    • Buy cheap Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving from wholesalers
    • Buy cheap Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving from wholesalers
    • Buy cheap Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving from wholesalers

    Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving

    Ask Lasest Price
    Brand Name : ESTEL
    Model Number : ET8010200A-38U
    Certification : ISO9001, CE, 3C, FCC, TLC, IP55
    Price : 358-2143 usd
    Payment Terms : T/T, L/C,D/A, Western Union, Paypal, etc
    Supply Ability : 5,000 sets per month
    Delivery Time : 15-20 working days
    • Product Details
    • Company Profile

    Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving


    38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving


    This cabinet is 2000mm High and 8000mm Wide and 1000mm Deep. This cabinet is the ultimate choice for outdoor racking requirements.


    Here is the brief introduction


    ● Heavy duty outdoor construction

    ● 38 rack units (RU), standard 19” rail

    ● Front access (rear access optional)

    ● Anti-theft three-point locking system, support padlock

    ● Outdoor powder coating, anti-corrosion

    ● Standard Color: light grey, RAL7035. Custom color available

    ● Cable inlet at cabinet bottom

    ● Include grounding bar

    ● Include door stopper

    ● Include four wheels on the bottom

    ● Optional cooling solutions: fan ventilation, air conditioner, heat exchanger


    Below is the technical parameter


    ConfigurationItemTechnical Parameter
    CabinetModelET8010200A-38U
    Protection LevelIP55
    External DimensionH2000mm×W800mm×D1000mm
    Internal Dimension19inch ,38U
    Material

    Galvanized steel, 1.2mm thickness, single wall.

    Thickness of bearing parts: 2.0mm

    InsulationPEF
    CoatingPolyester powder coating
    ColorRAL7035
    LockAnti-theft three-point locking system
    HingeInner hinge
    Installation OptionsFloor mounted
    Cable RoutingCable in and out from the bottom of cabinet
    MaintenanceOne front door, one rear door
    Cooling

    AC

    air conditioner

    1500W 220VAC 50Hz , install on the front door
    OthersLED lamp
    The entrance guard switch
    EnvironmentWorking Temperature-40℃~+55℃ (+Solar Radiation)
    Storage Temperature-40℃~+70℃
    Working Humidity5%~95%(No condensation)
    Working Altitude0~4000 meters

    Standard compliance table


    StandardDescription
    GB/T 17626.7-1998Electromagnetic compatibility
    GB4706.1Safety of household appliance and electrical appliance with similar use.
    GB4798.1Environmental conditions existing in the application for electric and electronic products - storage
    GB4798.2Environmental conditions existing in the application for electric and electronic products - transportation
    GB4798.3Environmental conditions existing in the application for electric and electronic products - usage


    Cabinet pictures




    Designing an outdoor telecom cabinet with a power supply inside involves several critical steps to ensure it is durable, functional, and able to withstand various environmental conditions. Here’s a comprehensive guide on how to design such a cabinet:

    1. Define Specifications and Requirements

    • Purpose and Usage: Determine the primary use of the cabinet, such as housing telecommunications equipment, power supplies, or both.
    • Environmental Conditions: Consider the climate, temperature, humidity, and potential for exposure to dust, water, or corrosive elements.
    • Size and Capacity: Determine the required size and capacity based on the equipment to be housed.
    • Regulations and Standards: Adhere to relevant industry standards and regulations, such as IP ratings for waterproofing and dustproofing.

    2. Select Materials and Construction

    • Cabinet Body: Use galvanized steel or stainless steel for durability and corrosion resistance.
    • Doors and Locks: Incorporate secure, weather-resistant locks and hinges. Consider using three-point locking systems for added security.
    • Cooling System: Install an air conditioner or fan to maintain a suitable operating temperature within the cabinet. Ensure it is rated for outdoor use and capable of handling the expected environmental conditions.
    • Sealing: Use gaskets and seals to prevent ingress of water, dust, and other contaminants.

    3. Power Supply Design

    • Power Source: Decide on the type of power supply (AC/DC), its capacity, and whether it will be integrated or separate.
    • UPS System: Consider incorporating an uninterruptible power supply (UPS) to provide backup power during outages.
    • Battery Compartment: Design a secure, ventilated battery compartment within the cabinet. Ensure it is easily accessible for maintenance and replacement.
    • Power Distribution: Include a power distribution unit (PDU) to manage and distribute power to various devices within the cabinet.

    4. Internal Layout and Organization

    • Mounting Rails: Install standard 19-inch mounting rails to accommodate telecommunications equipment.
    • Cable Management: Provide cable trays, clips, and guides to organize and route cables within the cabinet.
    • Grounding: Ensure the cabinet is properly grounded to protect against electrical hazards.

    5. Environmental Protection

    • Waterproofing: Aim for an IP rating of at least IP55 or higher to protect against water ingress.
    • Dustproofing: Use filters and seals to prevent dust and debris from entering the cabinet.
    • Temperature Control: Incorporate temperature sensors and alarms to monitor and control the internal temperature.

    6. Safety Features

    • Lightning Protection: Install lightning arresters or other protective devices to safeguard against lightning strikes.
    • Fire Protection: Consider using fire-resistant materials and incorporating fire detection and suppression systems.
    • Warning Labels and Signs: Provide clear, visible warning labels and signs to indicate potential hazards and operating instructions.

    7. Testing and Validation

    • Environmental Testing: Subject the cabinet to various environmental conditions to ensure it performs as expected.
    • Functionality Testing: Test all components and systems within the cabinet to verify their functionality and compatibility.
    • Compliance Testing: Ensure the cabinet complies with relevant industry standards and regulations.

    Quality Standard 38U Outdoor Data Cabinet With DC Air Conditioner And Wheels Easy For Moving for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)