    Brand Name : ESTEL
    Model Number : 1h16QPTKN1D1-8E2G
    Certification : ROHS
    Price : 43-1429 usd
    Payment Terms : L/C, D/A, D/P, T/T, MoneyGram
    Supply Ability : 3,000 sets per month
    Delivery Time : 15-20 working days
    • Product Details
    • Company Profile

    200-240VAC 2x16A Dual-Input Switched Rack PDU with KN-1 Protection Monitoring

    200-240VAC 2x16A Dual-Input Switched Rack Power Distribution Unit


    1. Power Distribution Unit Product Specification Parameter Description:


    Customer nameNO.Product specification parameter description
    Product namePower switch1Socket system and numberIEC320 C19 (2); IEC320 C13(8)
    Product specification and model1h16QPTKN1D1-8E2G2Internal connecting line16AWG,14AWG,copper Stick
    Product code3Power supply input modeC20 socket
    Product quantity4Cable plug system/
    RoHSYES5Cable specifications/
    Customer product code/6Cable installation modeBack dual input
    Customer product specification and model
    7

    Cable fixing

    /
    8Shell colorBlack
    Special product descriptionRemovable controller9Size and specification(L*W*H)484*250*44mm
    10Fixed hole center distance465mm
    11Aluminum alloy shell length/
    12Product installation modeBracket installation
    13Installation direction of bracketHorizontal formal
    Factory accessories4 pcs for each M6 screw and nut14Control indication function1P/16A CB(Prevent misoperation)
    15Protection monitoring functionKN-1
    Product identificationProduct namePower switch
    Customer specifications and models1h16QPTKN1D1-8E2G
    Rated voltage and current200-240VAC 2*16A
    Safety certification mark/
    LOGO/
    ManufacturerESTEL

    2. Power Distribution Unit Product Renderings:



    3. Intelligent PDU Function Comparison Table:


    FeaturesDescriptionPerformance ParametersKN series gradeNotes
    1
    Operating supply voltageThe voltage required for the normal operation of the productAC230V or AC400V

    Maximum input and output currentProducts can work long-term current

    16A or 32A

    Or 3x16A or 3x32A

    Operating power frequencyThe voltage required for the normal operation of the product47~63Hz
    Access interfaceNetwork portAccess monitoring via Ethernet or LAN10/100Mb network adaptation
    Network portLevel even portBuilt-in network switchReserving
    Serial portAccess through the serial port monitoringRS485 interface
    RS232 interface ( select one with RS485 interface)Selection
    Peripheral interfaceSensor interfaceRS485 interface
    interview method

    HTTP/

    HTTPS

    Browser mode accessCompatible with IE , FireFox and other popular kernel browsers , supporting SSL
    TELNETSimple command line access/
    SSHEncrypted command line accessSupport SSHv2 version
    SNMPSupports common simple network management protocol centralized monitoringCompatible with protocol versions such as SNMPv1/v2c/v3
    Operating system compatibilitySupports multiple operating systemsThe monitoring terminal is compatible with mainstream operating systems such as Windows//win7/linux
    Secondary developmentFor customer system integrationDevelopment agreement TELNET, SSH
    RS485Support customer agreement customization
    Software upgradeManagement software loadingSupport management software updates
    controlControl each output on and offEach output breaking capacity 16A 250VAC
    Power up and down in sequenceSequential power-off time interval 0.5s , sequential power-on time interval 1~60s can be set to prevent the power equipment from simultaneously starting the interference equipment, polluting lines, and the total brake line is not on
    Power offAfter the PDU input is powered off and restarted, the state of each output switch maintains its original state.
    MonitoringDetect each output fuse stateCan detect that the fuse is disconnected or the output switch does not turn on and off properly
    Monitor input voltage

    Resolution : 1V

    Accuracy: ± 1% +1 word

    Range: 90~350V

    Monitor the total input and output current

    Resolution : 0.1A

    Accuracy: ± 1% +1 word

    Measuring range: 0.1~40A

    Monitor each output current

    Resolution : 0.1A

    Accuracy: ± 1% +1 word

    Measuring range: 0.1~20A

    Monitor each electrical enery

    Resolution : 0.1KW ·H

    Accuracy: Level 1

    Monitor each active power

    Resolution: 1W

    Accuracy: ± 1% +1 word

    Monitor each power factor

    Resolution: 0.001

    Accuracy: ±1%+3 words

    Monitoring total power

    Resolution : 0.1KW ·H

    Accuracy: Level 1

    Monitor breaker status/Have not ,but optional
    Monitoring ambient temperature

    Resolution : 1 °C

    Accuracy: ± 1% +1 word

    Measuring Range: -30~100℃

    Have not ,but optional
    Monitoring environmental humidity

    Resolution : 1%

    Accuracy: ± 1% +1 word

    Measuring Range: 01-99%

    Have not ,but optional
    Monitoring environmental smokeMaximum effective 25㎡Have not ,but optional
    Monitoring environmental floodingCan monitor dew, water immersion environmentHave not ,but optional
    Infrared monitoring of environmental personnel enteringMaximum detection distance 16mHave not ,but optional
    Door and window monitoringMinimum opening distance 5mm effectiveHave not ,but optional
    Anti-surge, lightning protection failure monitoringDoes not affect the normal use of the product after failureHave not ,but optional
    Alarm limitTotal current limitAutomatic identification of limits
    Each output current limitAutomatic identification of limits
    Environmental temperature limitsAutomatic identification of limits
    Environmental humidity limitsAutomatic identification of limits
    Alarm outputEach fuse alarm

    PS/PN local alarm mode: PDU alarm site inspection, output sound and light, dry contact.

    PN remote alarm mode: E-mail, SMS, SNMP TRAP , WEB page prompt, TELNET/SSH prompt

    Each output current limit alarm
    Total current overload warning
    Temperature overrun alarmHave not ,but optional
    Humidity limit alarmHave not ,but optional
    Smoke alarmHave not ,but optional
    Flooding alarmHave not ,but optional
    People enter the alarmPN remote alarm mode: E-mail, SMS, SNMP TRAP , WEB page prompt, TELNET/SSH promptHave not ,but optional
    Open door / window alarmHave not ,but optional
    Anti-surge, lightning failure alarmHave not ,but optional
    Display, instructionsOutput indicatorOne output per indicatorHave not ,but optional
    LCD displayDisplay current voltage, display product information, alarm information
    Digital tube displayDisplay current voltage, display product information, alarm information
    Key menu operationsearch informationQuery display product information, alarm information, current, etc.
    On / Off alarm sound and dry contactTurn off / on alarm sound and dry contact output. Dry contact output has two options, normally open and normally closed. Passive, contact can be connected to 2A 250VAC.
    ProtectionLightning surge

    Differential mode: ± 2kV

    Common mode: ± 2KV

    Through traffic : 3KA

    Discharge current: 5KA

    Have not ,but optional
    Each with a fuse

    Insurance tube breaking force 1500A;

    To prevent the main line from being powered off, disasters occur in the power equipment and lines, and the fuse can be equipped with 0.1~16A

    Have not ,but optional
    Circuit breaker protectionSwitch the power supply to prevent short circuit affect the main line, to prevent electrical equipment overload disaster, breaking force 5000AHave not ,but optional
    Recoverable overload protectionPreventing Overload from Electrical Equipment and DisastersHave not ,but optional
    RecordAlarm logCyclic alarm log, you can query, export, save, delete
    ManagementUser management authorityDistinguish between administrator and general personnel rights
    Output group management/
    Clock synchronizationCorrect product system clock
    Named managementSupports naming operations such as PDUs , output bits, and sensors for easy management
    Intelligent RecognitionIntelligent identification outputAutomatically identify the output format, number of digits
    Intelligent identification sensorThe sensor interface does not need to be defined. The access can identify the sensor type and quantity.
    Intelligent identification limitsWhen the limit is out of range, the setting is invalid
    Intelligent identification of the product's maximum output current and current product access device powerHelps managers control the number or type of product access
    Intelligent identification of power factorHelp customers understand the power consumption of customer equipment and can be used as a reference for energy consumption
    Sensor access1~8 same or different types of sensors connected at the same timeSensor access, expansion, and flexibility to design new sensors based on new customer needsHave not ,but optional

    Quality 200-240VAC 2x16A Dual-Input Switched Rack PDU with KN-1 Protection Monitoring for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)